Gas/Oil Hot Water Boiler
- Model:WNS
- Capacity:0.35MW-14MW
- Fuel:Natural gas,LPG,CNG,LNG,hydrogen,biogas,city gas,diesel oil,heavy oil,dual fuel,etc
- Rated outlet temp.:95℃
- Return Water temp.:70℃
Application:
The Gas/Oil Hot Water Boiler can be used for the following business:Chemical plant,Textile plant,Food & Beverage,Garment manufacturing,Paper Plant,Printing and dyeing mill,Cement Plant,Fertilizer plant,Feed mills,Rubber factory.Schools,Hotel,Bath Center,Swimming Pool,Hospital,Hotel,etc.
The most important thing is that our boilers are all tailor-made.They are designed all depending on your business,including on the fuel,capacity,pressure and so on you need.
Following are the diagrams,accessories,valves about the boiler:
Diagrams:
Details about the boiler:
This boiler is horizontal type,fire tube,three pass shell boiler.It can burn heavy oil,light oil,city gas,natural gas,lpg,lng,cng(depend on the burner selected).Boiler furnace is corrugated furnace,burning under positive pressure,fully automatic control.
Then,here are the accessories and valves about the Gas/Oil Hot Water Boiler:
Customer visit:
Intimate tips for you here:
If you still have any question after browsing our website,you can send massege to us,we will give you the best suggestion with regard to you specialized.
Email to me at any time:service@yuanda-boiler.com
This boiler flue gas flow have three pass, fuel oil atomized by the burner burn in the corrugated furnace( first pass),then go to the reversal chamber for fire tube( second pass),then go into front chamber for fire tube again(third pass),then go to reversal chamber to chimney. There are chamber door and hole for maintance.
WNS series hot water boiler technology parameter table | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Boiler model | Rated capacity | Rating pressure | Rated outlet temp. |
Return Water temp. |
Fuel consumption | Thermal efficiency | Weight | Dimensions | ||||
Light oil | Heavy oil | natural gas | liquefied gas | City gas | ||||||||
MW | MPa | ℃ | ℃ | Kg/h | Kg/h | m3/h | m3/h | m3/h |
% |
t | mm | |
WNS0.7-0.7/95/70-Y(Q) |
0.7 | 0.7 | 95 | 70 | 65.5 | 67.3 | 84.2 | 29 | 176 | 92 | 4.3 | 3561×1690×1910 |
WNS1.4-0.7/95/70-Y(Q) |
1.4 | 0.7 | 95 | 70 | 129.6 | 132.2 | 165 | 57.3 | 346 | 92 | 7 | 4111×1950×2199 |
WNS2.8-0.7/95/70-Y(Q) |
2.8 | 0.7 | 95 | 70 | 256 | 261.9 | 323.6 | 109 | 682 | 92 | 9.5 | 4732×2150×2448 |
WNS4.2-0.7/95/70-Y(Q) |
4.2 | 0.7 | 95 | 70 | 380 | 390.6 | 450 | 164 | 1020 | 93.5 | 16 | 5500×2600×2990 |
WNS5.6-1.0/95/70-Y(Q) |
5.6 | 1 | 95 | 70 | 503 | 517 | 642 | 209 | 1321 | 93.5 | 24.6 | 6450×2800×3200 |
WNS7-1.0/95/70-Y(Q) |
7 | 1 | 95 | 70 | 628 | 643 | 805 | 264 | 1654 | 94 | 26.2 | 6800×2900×3394 |
WNS10.5-1.0/95/70-Y(Q) |
10.5 | 1 | 95 | 70 | 940 | 965 | 1182 | 400 | 2417 | 94 | 37 | 7150×3200×3540 |
WNS14-1.0/95/70-Y(Q) |
14 | 1 | 95 | 70 | 1250 | 1301 | 1597 | 520 | 3299 | 94 | 55 | 8200×3400×3826 |
Notes: The lower heating value of the fuel is calculated by the following values, light oil 10240kcal/kg, heavy oil 10000 kcal/kg, natural gas 8000kcal/Nm3, liquefied gas 24000 kcal/Nm3, and city gas 3800 kcal/Nm3. The parameters are for reference only. If the technology is improved, please refer to random technical parameters.